Standalone CAN Bus Message Sending Without a PC

Standalone sending lets a CAN dongle transmit a stored list of messages on its own, with no computer running. That helps when a PC is not available, when timing must not depend on Windows, or when a test setup has to run unattended. Both the dual-channel USB CAN FD analyzer and the Lab CAN Pro support standalone send mode in SLSS CANAnalyser.

What standalone sending does

You build a list of up to 40 messages in the Standalone Send Mode tab, send it to the dongle, and disconnect from the software. The dongle then powers up and transmits the list autonomously, powered from its USB connector or the DB-9 connector. When you reconnect to SLSS CANAnalyser, the dongle behaves normally again and you can reconfigure it.

What you can set up

  • CAN 2.0 or CAN FD messages, each with its own ID and data. A message can be marked as CAN FD, with the bit rate switch option.
  • A start delay between power-up and the first transmitted message.
  • Separate hardware settings for standalone mode (CAN 2.0 or CAN FD, bit rates), independent of the settings you use while connected.

CAN FD data lengths

For CAN FD, the manual explains that data beyond 8 bytes must be fully populated up to the next valid length: 12, 16, 20, 24, 32, 48 or 64 bytes. Bytes beyond the last valid length are truncated, so fill in every byte up to the next length.

Temporary or committed lists

  1. Temporary: the list stays on the dongle only while it is powered. It is lost when power is removed.
  2. Committed: the list is stored permanently on the dongle until you overwrite or erase it. From then on, standalone mode is the default whenever the dongle powers up, and connecting to the software still gives normal functionality.

You can retrieve a stored list from the dongle, erase it (which disables standalone mode until you send a new list), and save or load lists as files. Saved Send Messages files (.CASF), Standalone files (.CSSF) and PEAK .XMT files can be opened.

Power and indicators

If the dongle is powered by a USB connection that is not connected to a PC, the USB supply must provide at least 250 mA for the CAN bus line outputs to work properly. While a message list is stored, LED 1 blinks purple, more slowly than in normal operation. The channel LEDs show red when sending, and amber if there is an error state when sending.

How it differs from macros

The Send CAN Messages tab also has six macro slots that send a saved message list once or repeatedly. Macros run from the software on your PC. Standalone sending runs on the dongle itself.

Frequently asked questions

Does it work with CAN FD?

Yes. Each message can be CAN 2.0 or CAN FD, with the bit rate switch option.

Where is the step-by-step procedure?

See the user’s manual on the Downloads page and our instructional videos.

Need help setting up a sequence? Contact technical support.

Shopping Cart